Quantcast
Channel: Desert Home
Viewing all articles
Browse latest Browse all 218

Water Heater and Solid State Relays

$
0
0
A few times I mentioned the solar water heater I have.  It works great and keep me in free hot water most of the time.  Yes, it's the desert and during the summer the coldest the water gets is lukewarm, but I get 140F water out of the heater for zero continuing expense except for the few days where it is overcast.

Those overcast days present a problem.  A couple of times I turned the power on to the water heater and used the helper coil to heat the water because the sun just didn't come out.  Once, it pushed my power bill up because an X10 controller didn't react to the turn off command.  This prompted me to hook the water heater power to the garage controller I have.  This worked fine.  I'm able to send an XBee signal and turn on the water heater.  I also have code in the garage controller that shuts the heater down during peak periods. It's working really great except...

The contactor I have started to buzz.  It works fine, but there is a constant 60Hz buzz coming from it any time it's on.  The first time I heard it, I had to hunt for a while to figure out what it was.  Then, as the days went by, it got more and more annoying.  For those of you that have no idea what a contactor is, here's a picture of the one I have.


They're really nothing much more than a really big relay.  They have specially built contacts to survive high current switching and lots of places to hook wires.  They are probably all over your house and you don't know it.  Appliances have them, some fireplaces, environmental heating, etc.  Most of them run on a 24V coil and last a really long time.  In my particular case, I used a 110V coil because I was originally switching it with an X10 appliance module.  Unfortunately, the 110V units tend to make noise as they age.  They're not wearing out, they just start to rattle at 60Hz and drive you nuts.  There is a solution, use a solid state relay instead.

So, I got online and started looking for an SSR that could handle 25A at 240VAC.  There's a lot of them out there, but I need two of them, one for each leg of the power.  That made converting expensive, but I kept looking and found a SSR for 240 VAC three phase.  This gives me three of them in a package and I only have to use two of them.  I don't know if I'll ever need the spare, but it's there if I need it.  Here's the device I bought:


Notice that is has inputs for three circuits and one control for all of them.  This is exactly what I wanted.  So, when it came in, I took the entire control assembly off the wall and rebuilt it essentially from scratch.  Here's what it looks like on the wall:



Simple isn't it?  Just one device with the control signal coming in the top and hooking up on the left side.  It only takes a little over 4VDC to turn it on and it doesn't make any noise at all.  Since there are no contacts, it should last forever just sitting there working it's little heart out.  

I probably should have used one of these to begin with, but I didn't have a clue XBees even existed when I started out on these projects.  I was convinced by the advertising and various articles on the web that X10 would do the job.  

It's sad that I was that naive.


Viewing all articles
Browse latest Browse all 218

Trending Articles